Installation Instructions for
60 Watt Electronic Direct Power Feed
Canopy Transformer
980MRLSFELEDDCT-LED
1
1.2
TRANSDIRSFE60_-LED
Install the Power Feed Canopy
#8-32 SCREW
NOTE: Use the provided universal round crossbar when the
canopy holes do not line up with the electrical box holes.
POWER LINE WIRES
Disconnect power to the electrical box.
Connect the white transformer wire to the neutral power line
wire with a wire nut.
Connect the black transformer wire to the hot power line
wire with a wire nut.
Connect a suitable ground in accordance with local electrical
codes.
Connect the canopy wires to the transformer output wires
with wire nuts.
Place the transformer, wires, and wire nut connections inside
the electrical box.
Mount power feed canopy to the electrical box with the two
#8-32 screws.
TRANSFORMER
GP I :ENERAL RODUCT NFORMATION
This product is ETL listed only when all the products used are
supplied by LBL Lighting, is suitable only for indoor dry locations
and approved for use at any height above the finished floor.
This product may be dimmed only with a low voltage electronic
dimmer. Using a dimmer not designed for low voltage electronic
applications may cause undesirable noise and potentially shorten
the life of the transformer.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
This product is intended for use with LBL low voltage lighting
systems only.
Read all instructions thoroughly before beginning installation.
Important Safety Information
To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.
Do not install fixture assemblies closer than 6 inches to curtains or
similarly combustible materials.
Turn the electrical power off before modifying the lighting system in
any way.
The fixtures used with the system must be identified to be used
with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.
1A1A
1
2
3
4
6
5
7
3
2
5
77
LED-Illuminated Monorail
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Important Safety Information

Installation Instructions for60 Watt Electronic Direct Power FeedCanopy Transformer980MRLSFELEDDCT-LED11.2TRANSDIRSFE60_-LEDInstall the Power Feed Can

Page 2 - Transformer Canopy

2Connect the MonoRail to theTransformer CanopyRemove the power feed cap from the power feed housing.Completely back out the screw on the power feed ca

Commentaires sur ces manuels

Pas de commentaire