Installation Instructions for
1
TRANSFORMERS
1.0
1.0
1.5
250AT600T277
950RM60012-277
Important Safety Information
Do not conceal or extend bus bar conductors through a
building wall.
Do not install this lighting system in a damp or wet location.
To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can
be shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to
curtains or similarly combustible materials.
Turn the electrical power off before modifying the lighting
system in any way.
The fixtures used with the system must be identified for use
with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches
(98 cubic centimeters).
To Reduce Risk of Fire, it is important to wire the remote
transformer for the system as described in this installation
instruction.
Load each circuit of the remote transformer to 300MAXIMUM
Watt.
277 Volt to 12 Volt Dual Feed 600W Remote Magnetic
Transformers
GP I :ENERAL RODUCT NFORMATION
This transformer is ETL listed for use with low voltage lighting
systems of brands offered by Generation Brands.
This product is suitable only for indoor dry locations and
approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in
accordance with the local electrical codes.
This product may be dimmed only with a low voltage magnetic
dimmer. Using a dimmer not designed for low voltage
magnetic applications may work initially, but could eventually
cause transformer failure and will void the warranty.
The
dimmer must be derated as indicated by the dimmer
manufacturer.
This product is intended for use with Generation Brands low
voltage lighting system brands only.
During installation, make sure all power connections are tight.
Read all instructions thoroughly. Read "Important Safety
Information" on next column before proceeding with the
installation.
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Important Safety Information

Installation Instructions for1TRANSFORMERS1.01.01.5250AT600T277950RM60012-277Important Safety InformationDo not conceal or extend bus bar conductors t

Page 2 - LOW VOLTAGE WIRE SIZE TABLE

2Install the Remote TransformerMount the transformer to a solid surface using thekeyhole slot on the mounting bracket (hardware notincluded).Remove th

Page 3 - TERMINAL TAP TABLE

COMX X1 X2 X3 X4COMY Y1 Y2 Y3 Y43Install a conduit from the transformer to the electricalbox.For the best performance, use the "Low Voltage WireS

Page 4 - Check the System

4Check the SystemCOMX X1 X2 X3 X4COMY Y1 Y2 Y3 Y410111213PHILLIPSSCREWCIRCUIT BREAKERCIRCUITBREAKERSAVE THESE INSTRUCTIONS!123444337400 Linder Ave, Sk

Commentaires sur ces manuels

Pas de commentaire